“CRYSTAL” makes Seamless Latex Hand Gloves for Electrical Purpose.Tested in Laboratory

Confirming I.S.S 4770 / 1968 / 1991 . & I.S.S 13774 / 1993

Following tests were performed for the LOT of 20  pair size 355 m.m

  1. Test Potential at 11000 Volts, R.M.S 50 cycle per second frequency. The Maximum Leakage Current was 08
  2. Tensile Strngth average 200 kgf/cm² after ageing test at 70 ° ± 1°C Tensil strength 190 Kgf /cm²
  3. Elongation Break 1000 percent average. After ageing test at 70 ° ± 1°C  Elongation at Break 950
  4. Tension set , max 5
  5. Puncture resistance 50 kN/m.
  6. Size – 355mm

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 5 KV
Working Potential Volts : 650 Volts
Type : 1
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 10 KV
Working Potential Volts : 1100 Volts
Type : 2
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 17 KV
Working Potential Volts : 7500 Volts
Type : 3
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 25 KV
Working Potential Volts : 17000 Volts
Type : 4
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 33 KV
Working Potential Volts :7500 Volts
As per IS 4770:1991 – 2002 Standard

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 33 KV
Working Potential Volts :11000 Volts
As per IS 4770:1991 – 2002 Standard

Electrical Hand Gloves – Secura Make
ELSEC 2.5
Class 00
Test Potential Volts : 2.5 KV
Working Potential Volts : 500 Volts
AS PER EN 60903: 2003+ AC2: 2005

Electrical Hand Gloves – Secura Make
ELSEC 20
Class 2
Test Potential Volts : 20 KV
Working Potential Volts : 17000 Volts
AS PER EN 60903: 2003+ AC2: 2005

Electrical Hand Gloves – Secura Make
ELSEC 30

Class 3
Test Potential Volts : 30 KV
Working Potential Volts : 26500 Volts
AS PER EN 60903: 2003+ AC2: 2005