Confirming I.S.S 4770 / 1968 / 1991 . & I.S.S 13774 / 1993
Following tests were performed for the LOT of 20 pair size 355 m.m
- Test Potential at 11000 Volts, R.M.S 50 cycle per second frequency. The Maximum Leakage Current was 08
- Tensile Strngth average 200 kgf/cm² after ageing test at 70 ° ± 1°C Tensil strength 190 Kgf /cm²
- Elongation Break 1000 percent average. After ageing test at 70 ° ± 1°C Elongation at Break 950
- Tension set , max 5
- Puncture resistance 50 kN/m.
- Size – 355mm


Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 5 KV
Working Potential Volts : 650 Volts
Type : 1
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 10 KV
Working Potential Volts : 1100 Volts
Type : 2
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 17 KV
Working Potential Volts : 7500 Volts
Type : 3
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 25 KV
Working Potential Volts : 17000 Volts
Type : 4
As per IS 4770:1991 – 2002 Standards

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 33 KV
Working Potential Volts :7500 Volts
As per IS 4770:1991 – 2002 Standard

Electrical Hand Gloves Electro Saviour Brand
Test Potential Volts 33 KV
Working Potential Volts :11000 Volts
As per IS 4770:1991 – 2002 Standard

Electrical Hand Gloves – Secura Make
ELSEC 2.5
Class 00
Test Potential Volts : 2.5 KV
Working Potential Volts : 500 Volts
AS PER EN 60903: 2003+ AC2: 2005

Electrical Hand Gloves – Secura Make
ELSEC 20
Class 2
Test Potential Volts : 20 KV
Working Potential Volts : 17000 Volts
AS PER EN 60903: 2003+ AC2: 2005

Electrical Hand Gloves – Secura Make
ELSEC 30
Class 3
Test Potential Volts : 30 KV
Working Potential Volts : 26500 Volts
AS PER EN 60903: 2003+ AC2: 2005